---+ Designing a Storage Area Network for the Department of Engineering Science ---++ Objective The objective of this project was to use mixed-integer programming (MIP) models to automatically design a minimum-cost storage area network (SAN). We designed this SAN as a possible alternative to the storage system that was used (up until 2007) by the <a href="https://www.esc.auckland.ac.nz/" target="_blank">Department of Engineering Science (DES)</a> in <a href="https://www.auckland.ac.nz/" target = _blank">The University of Auckland</a>. ---++ Problem Description When we started this project in 2006 the DES storage system consisted of: * 3 servers, two used as domain controllers (Server 1 for staff and Server 2 for students, respectively), and one server (Server 3) used purely for data storage; * Server 1 and Server 2 both contain two "plug-and-play" hard drives. The drives have 300 GB of memory and their disks run at 10000 rpm; * Both Server 1 and Server 2 mirror their data, i.e., both hard drives in a server contains a copy of the data accessed by that server; * A new storage device (with 15 TB of storage) was to be added to the storage system. While the mirroring of the disks gives this system some reliability, if either Server 1 or Server 2 fails or requires maintenance, then the data contained on the disks within that server is unavailable. However, having directly attached storage meant that access times for the data are fast. In this project we wanted to design an alternative storage system that was cost-effective and reliable. ---+++ Storage Devices To replicate the functionality of the current DES storage system we need to have two storage devices and one backup storage device. The two storage devices must model the behaviour of the current embedded storage devices, so they will be disk arrays with two 300 GB, 10000 rpm disks. The backup storage device will be identical to the storage device being added to the current storage system. ---+++ Servers The new storage system will be connected to the original servers (Server 1, Server 2, and Server 3 respectively) and also connected to two new servers (New Server 1 and New Server 2). The new servers will initially be used for running iSCSI software, iSCSI Target, and testing the SAN before it is connected to the DES servers. Once the decision to use the SAN has been made the new servers will be used predominantly for running iSCSI Target. ---+++ Reliability Each server and storage device must have two connections to the SAN fabric to allow for 2(+) disjoint paths between any server/storage device pair. ---+++ Switches, Hubs and Links Initially we used a fully-connected single-edge Core-Edge topology for our SAN design: * _Fully-Connected_ means that all the server ports and all the storage device ports are connected to the SAN; * _Single-Edge_ means that both server ports and storage device ports connect to a single layer of edge switches; * _Core-Edge_ is a topology using _edge_ switches to connect to hosts (e.g., servers, client machines, etc) and devices (e.g., storage devices such a disks, disk arrays, etc) and _core_ switches to connect the edge switches to each other. All links go between the hosts/devices and the edge switches or the edge switches and the core switches. To preserve network symmetry, all edge switches are the same switch type and all core switches are the same switch type (although the core switch type may be different from the edge switch type). There are no hubs in a Core-Edge topology. For the DES storage network, we sourced appropriate ethernet switches and links via the internet and came up with the following list of possible switches: | *Switch Types* | *Cost ($)* | *Ports* | | Cameo | 73.83 | 5 | | DLink | 89 | 8 | | CNet | 275 | 16 | | Linksys | 366.35 | 24 | All switches have the full complement of ports pre-configured (so there is no cost per port) and run at 1Gbps. We decided to use Cat6e (1 Gbps) cable for the links. ---++ Approach We want to design a fully-connected, single-edge, Core-Edge SAN from ethernet switches to connect 5 servers to 3 storage devices. We will use Cat6e ethernet cable to link the servers, storage devices and ethernet switches and select our switches from a list of possible switch types. We developed a MIP model for core-edge SAN design in <a href="https://www.ampl.com" target = _blank">AMPL</a> and solved it using the <a href="https://www.ilog.com/products/cplex/" target = _blank">CPLEX solver</a>. For a full discussion of our models and results, see our <a href="#publications">publications</a> on SAN design. ---++ Outcomes We solved this problem using mixed-integer programming. The resulting configuration of the Core-Edge SAN is shown below: <img src="%ATTACHURLPATH%/san_configuration_small.jpg" alt="san_configuration_small.jpg" width='905' height='522' /> [[%ATTACHURLPATH%/san_configuration.jpg][Here]] is a full size image (approximately A3 size). After finding this network, we wanted to see how much traffic it could handle reliably. Using another MIP, we found that the network could handle 200 MB/s of data traffic between all server-storage device pairs with diverse protection reliability (i.e., 2 node disjoint paths to support each flow). The data flow diagram is shown below: <img src="%ATTACHURLPATH%/san_flows_small.jpg" alt="san_flows_small.jpg" width='949' height='476' /> [[%ATTACHURLPATH%/san_flows.jpg][Here]] is a full size image (approximately A3 size). In 2007 NDSG received a grant from <a href="https://www.auckland.ac.nz/" target = _blank">The University of Auckland's</a> <a href="https://www.engineering.auckland.ac.nz/" target = _blank">Faculty of Engineering</a> CAPEX fund to implement the core-edge SAN we designed in this project. The details of the implementation work can be found in the [[DESStorageImplement][Implementing a Storage Area Network Prototype]] project. ---++ Publications <a name=publications> </a> * <a target="_blank" href="https://www.sciencedirect.com/science/journal/03050548">A Mixed-Integer Approach to Core-Edge Design of Storage Area Networks</a>, C. G. Walker, M. J. O’Sullivan and T. D. Thompson, Computers and Operations Research 34 (10), 2976-3000, 2007 * <a target="_blank" href="https://linkinghub.elsevier.com/retrieve/pii/S030505480900183X">Core-Edge Design of Storage Area Networks - A Single-Edge Formulation with Problem-Specific Cuts</a>, C. G. Walker, M. J. O’Sullivan and T. D. Thompson, Computers and Operations Research 37 (5), 916-926, 2010 -- Main.MichaelOSullivan - 14 Dec 2010
Attachments
Attachments
Topic attachments
I
Attachment
History
Action
Size
Date
Who
Comment
jpg
san_configuration.jpg
r1
manage
955.3 K
2010-12-15 - 01:46
MichaelOSullivan
jpg
san_flows.jpg
r1
manage
1351.1 K
2010-12-15 - 01:48
MichaelOSullivan
Edit
|
Attach
|
Watch
|
P
rint version
|
H
istory
:
r5
<
r4
<
r3
<
r2
<
r1
|
B
acklinks
|
V
iew topic
|
Raw edit
|
More topic actions...
Topic revision: r4 - 2011-01-12
-
MichaelOSullivan
Home
Site map
Forum web
Main web
NDSG web
ORUA web
OpsRes web
Sandbox web
TWiki web
ORUA Web
Create New Topic
Index
Search
Changes
Notifications
RSS Feed
Statistics
Preferences
P
P
View
Raw View
Print version
Find backlinks
History
More topic actions
Edit
Raw edit
Attach file or image
Edit topic preference settings
Set new parent
More topic actions
Account
Log In
Edit
Attach
Copyright © 2008-2025 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding TWiki?
Send feedback